M50100thc1600 Power Diode Module Bridge Rectifier M50100tha1600 M50100tb1200 M50100tb1600 M50100sb1200 M50100sb1600 9y0916 Ck158 Cy8713 Cy8705 9y9412

Product Details
Customization: Available
Conditions
of Use:
Car Type, Trailer Type, Marine, Land Use
Usage: Emergency Crew, Standby Unit, Common Units
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Group Corporation
Secured Trading Service
Gold Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
200000000 RMB
Plant Area
>2000 square meters
Find Similar Products

Basic Info.

Model NO.
M50100THA1600 M50100TB1200 M50100TB1600 M50100SB12
Output Type
AC Three Phase
Cooling
Method
Air Cooled
Installation
Method
Portable
Generator
Type
Diesel Generator
Transport Package
Carton
Specification
10*10*10MM
Trademark
Baishan Power
Origin
China
HS Code
8503009090
Production Capacity
38000PCS/Year

Packaging & Delivery

Package Size
2.00cm * 2.00cm * 5.00cm
Package Gross Weight
0.500kg

Product Description

9Y9412:

 

Description

 

Product Description
M50100CC400 Diode Module 100A 120 VAC 
M50100CC600 Diode Module 100A 240 VAC
M50100CC1000 Diode Module 100A 380 VAC
M50100CC1200 Diode Module 100A 480 VAC
M50100CC1400 Diode Module 100A 530 VAC
M50100CC1600 Diode Module 100A 600 VAC
M50100DD400 Diode Module 100A 120 VAC 
M50100DD600 Diode Module 100A 240 VAC
M50100DD1000 Diode Module 100A 380 VAC
M50100DD1200 Diode Module 100A 480 VAC 
M50100DD1400 Diode Module 100A 530 VAC
M50100DD1600 Diode Module 100A 600 VAC 
M50100SB400 Diode Module 100A 120 VAC
M50100SB600 Diode Module 100A 240 VAC
M50100SB1000 Diode Module 100A 380 VAC 
M50100SB1200 Diode Module 100A 480 VAC
M50100SB1400 Diode Module 100A 530 VAC
M50100SB1600 Diode Module 100A 600 VAC
M50100TB400 Diode Module 100A 120 VAC
M50100TB600 Diode Module 100A 240 VAC 
M50100TB1000 Diode Module 100A 380 VAC
M50100TB1200 Diode Module 100A 480 VAC
M50100TB1400 Diode Module 100A 530 VAC 
M50100TB1600 Diode Module 100A 600 VAC
M50100THC400 Diode Module 100A 120 VAC
M50100THC600 Diode Module 100A 240 VAC
M50100THC1000 Diode Module 100A 380 VAC
M50100THC1200 Diode Module 100A 480 VAC
M50100THC1400 Diode Module 100A 530 VAC
M50100THC1600 Diode Module 100A 600 VAC
M5060CC400 Diode Module 50A 120 VAC
M5060CC600 Diode Module 50A 240 VAC
M5060CC1000 Diode Module 50A 380 VAC
M5060CC1200 Diode Module 50A 480 VAC
M5060CC1400 Diode Module 50A 530 VAC
M5060CC1600 Diode Module 50A 600 VAC
M5060DD400 Diode Module 50A 120 VAC
M5060DD1000 Diode Module 50A 380 VAC
M5060DD1200 Diode Module 50A 480 VAC
M5060DD1400 Diode Module 50A 530 VAC
M5060DD1600 Diode Module 50A 600 VAC
M5060SB400 Diode Module 50A 120 VAC 
M5060SB600 Diode Module 50A 240 VAC
M5060SB1000 Diode Module 50A 380 VAC
M5060SB1200 Diode Module 50A 480 VAC
M5060SB1400 Diode Module 50A 530 VAC
M5060SB1600 Diode Module 50A 600 VAC
M5060TB400 Diode Module 50A 120 VAC
M5060TB600 Diode Module 50A 240 VAC
M5060TB1000 Diode Module 50A 380 VAC
M5060TB1200 Diode Module 50A 480 VAC
M5060TB1400 Diode Module 50A 530 VAC
M5060TB1600 Diode Module 50A 600 VAC
M5060THC400 Diode Module 50A 120 VAC
M5060THC600 Diode Module 50A 240 VAC
M5060THC1000 Diode Module 50A 380 VAC
M5060THC1200 Diode Module 50A 480 VAC
M5060THC1400 Diode Module 50A 530 VAC
M5060THC1600 Diode Module 50A 600 VAC

 

 Rectifier 9Y0916

 


GAS ENGINE  G3408   G3408B   G3412   
GEN SET ENGINE  3408   3412   3412C   3456   
GENERATOR  SR4   
GENERATOR SET  3406C   3408C   3412   3412C   3508   3512   3516   C15   C18   C27   G3412   G3512   G3516   
MARINE ENGINE  3408C   3412C   
PETROLEUM GEN SET  C18   
POWER MODULE  PM3412   

The diodes on the main rectifier assembly can be checked with a multimeter. The flexible leads connected to each diode should be disconnected at the terminal end, and the forward and reverse resistance checked. (See section 2, diode testing).  The rectifier assembly is split into two plates, positive and negative, and the main rotor is connected across these plates.  Each plate carries 3 diodes, the negative plate carries the negative based diodes, and the positive plate carries the positive based diodes.  Care must be taken to ensure that three identical polarity diodes are fitted to each plate. When fitting the diodes to the plates they must be tight enough to ensure a good mechanical and electrical contact, but should not be over tightened.  The recommended torque tightening is 4.06 to 4.74 Nm, (14 to 17 kg/cm).

 

The Surge Suppressor (Varistor) in the  Rectifier Kit RSK1101, is a protection device, which prevents high voltage transients from damaging the main rectifier diodes.  High Voltage transients are created by fault conditions in the distribution system. The Voltage transient returns back to the Generator output terminals, enters the main stator windings, and by mutual inductance, is transferred to the main rotor windings, and the main rectifier assembly.

The Surge Suppressor of  Rectifier Kit RSK1001 can be tested with a Multimeter on Megohms range.  A good Surge Suppressor should have a very high resistance, (more than 100 Megohms in either direction).  A faulty Surge Suppressor will be either open circuit (usually showing signs of burning) or short circuit in both  directions. 
The Main Rectifier in the  RSK1001 Rectifier Kit will work normally with this device removed.  However, it should be replaced as soon as possible, to avoid diode failure in the event of further transient fault conditions.   Occasionally, a very high transient may totally destroy the Surge Suppressor. This would result from extreme fault  conditions, such as lightning, (electric storms), close to overhead distribution lines, or out of phase synchronisation of the Generator, when paralleled to multiple Generator systems, (or the Mains, Utility, supply). 

Installation for  Rotating Diode Rectifier

Factory View:

M50100thc1600 Power Diode Module Bridge Rectifier M50100tha1600 M50100tb1200 M50100tb1600 M50100sb1200 M50100sb1600 9y0916 Ck158 Cy8713 Cy8705 9y9412
M50100thc1600 Power Diode Module Bridge Rectifier M50100tha1600 M50100tb1200 M50100tb1600 M50100sb1200 M50100sb1600 9y0916 Ck158 Cy8713 Cy8705 9y9412
M50100thc1600 Power Diode Module Bridge Rectifier M50100tha1600 M50100tb1200 M50100tb1600 M50100sb1200 M50100sb1600 9y0916 Ck158 Cy8713 Cy8705 9y9412
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed